Ceiling, Ideas: Extraordinary Ceiling, Wiring, Wire Throughout, Wire In Ceiling Light - If it helps, there are capped crimson and black wires in the two mild transfer bins that must power these fans (there are 3 ceiling outlet packing containers overall). The furniture had been removed before we moved in, so i haven't any concept how any previous fans had been wired. Hoping i will get some help right here. Trying to determine out the wiring in my outlet box for a ceiling fan installation. I've black wires, crimson wires, white wires, and then a naked wire for ground.

My rest room simplest has a mild transfer in it.? i would like to replace this switch with a transfer & gfci outlet blend.? i bought the t7299.? the primary problem i see is that there isn't always a ground cable within the switch box.? from studying an earlier put up, it looks like this need to be good enough.? the alternative trouble i have is that the wires within the field don't healthy any wires in the instructions.? i've two purple wires going to the transfer.? not three or 4, or inexperienced, black or white.? ok, there may be a white cord however it comes in and right back out of the box.? with any luck these snap shots can help. Mainly burdened with the aid of the 2 black and two purple. I might want to the fan and lights on independent switches, which appears workable with this set-up, however confused by way of the presence of the two pink wires.

I'd probable start through getting a non-touch voltage detector (or brief lamps) and notice which wires inside the ceiling are warm in various mixtures of switches being thrown. Figure out which one is energized by the transfer you want to throw the most, and designate that the lamp circuit. The other is the fan. You possibly may not need to alternate a issue inside the switches. Your very clean pics display a red-white pair coming from a energy supply and going to a mild fixture, with a transfer inserted into the pink (warm) lead.? you need to figure out which pair (which conduit, left or right) is coming from the strength supply and which one goes to the mild fixture.? use a probe able to piercing the insulation at the white wire (or just reduce it, because you need to reduce it besides to put in the gfci outlet).? turn off the mild and degree the voltage among the white wire and each of the pink wires.? the crimson-white pair that has voltage on it's far the pair coming from the energy source.? transfer off the circuit breaker and connect this pink-white pair to the line terminals of the gfci.? connect the white twine from the light fixture to the white wire on the gfci.? join the switch between the pink wire coming from the light fixture and the pink wire on the gfci.? you are proper, the dearth of a ground twine is good enough; a gfci may be used for a -twine outlet.? see the sketches under.? the hardest part of this activity can be enlarging the hole inside the tile with out cracking adjacent tiles, getting rid of the single field, and installing a double container for the gfci outlet and transfer.